130 MW
Campus Capacity
1.15 PUE PUE
PUE Guaranteed
Download Spec Sheet
100 MW
Campus Capacity
1.15
PUE Guaranteed
3
Data Centers

Prime location

  • Located at a high speed fiber crossroads including the ultra-low latency link to North America and Northern Europe data hubs

  • The Bilbao-Arasur campus includes three data center buildings and one administrative building, providing ample room to grow

  • Adjacent to a planned 135 MW solar farm delivering affordable clean energy

  • Diverse protected links to Edged sites in Madrid, Barcelona and Lisbon

© Mapbox, © OpenStreetMap
© Mapbox, © OpenStreetMap

Bilbao-Arasur Campus

Supermanzana 6 Plataforma Logística Arasur
Avenida Ribera Baja S/N, 01213 Rivabellosa, (Álava, Spain)

  • 100 MW of critical capacity at the Arasur industrial/logistics hub South of Bilbao, providing sustainable EV charging and IT infrastructure.
    • BIL03: 22 MW
    • BIL02: 48 MW (BTS)
    • BIL01: 60 MW (BTS)
  • New build construction; three stories, concrete slab and structural steel; two loading dock bays
  • 24 x 7 x 365 access; 2 meet-me rooms
  • Multiple fiber providers; three diverse points of entry
  • Tier III design concurrently maintainable
  • 100% uptime SLA
  • BIL01: TBD (BTS) | BIL02: 48 MW (BTS) | BIL03: 22 MW
  • New build construction; three stories, concrete slab and structural steel; two loading dock bays
  • 24 x 7 x 365 access; 2 meet-me rooms
  • Multiple fiber providers; three diverse points of entry
  • Tier III design concurrently maintainable
  • 100% uptime SLA
Take the virtual tour

Clean and Reliable Power

  • Adjacent to a planned 135 MW solar farm
  • Battery backup supporting all electrical and mechanical systems
  • UPS with N+1 redundancy
  • Generators with N+1 redundancy
  • Standby generation systems utilize Tier 4 Final engines which reduce NOx and particulate matter emissions by up to 99%
  • Redundant A+B side distribution
  • Revenue-grade, transparent, real-time metering

Tier 4 Final EPA Emission versus other tiers

World Class Security & Fire Protection

  • Perimeter fencing and exterior access gates
  • Interior biometric readers, ID badges, CCTV
  • Data halls have double-interlock pre-action mist system
  • Addressable smoke detectors with hot aisle early detection

Advanced Waterless Cooling System

  • Water Usage Effectiveness (WUE) 0.00 liters/kWh of cooling
  • N+1 redundancy
  • Glycol heat transfer with rooftop air cooled chillers
  • Closed loop evaporators provide secondary cooling
  • 500 kW capacity per hot aisle (modular)
  • Uninterruptible maintenance service outside of white space
  • ThermalWorks systems use non-toxic glycol with zero Global Warming Potential (GWP) and some of the lowest GWP refrigerants available anywhere (R1234ze or R515-B)
Learn More

Cooling system Coefficient of Performance (COP)

99.9999

Estimated “six nines” of availability with Tier III design standards and N+1 power, UPS and cooling systems

Continuous systems monitoring and secure DCIM controls platform covering all mechanical and power systems

Leading energy efficiency in any climate

Our facilities are designed to deliver industry-leading average 1.15 PUE portfolio-wide, using no water for cooling. This reduces energy overhead by 74% compared with the global average. Uptime Institute, “The average annual power usage effectiveness (PUE) reported in 2023 was 1.58”

Learn More
1 Uptime Institute, “The average annual power usage effectiveness (PUE) reported in 2023 was 1.58”

Advanced waterless cooling

Traditional data center cooling consumes vast quantities of water, putting significant pressure on local resources. To address this growing issue, we use the ThermalWorks modular cooling system that supports the dense AI-driven loads that are reshaping the IT industry yet consumes no water.

Traditional data center cooling consumes vast quantities of water, putting significant pressure on local resources. To address this growing issue, Edged uses our ThermalWorks modular cooling system that supports the dense AI-driven loads that are reshaping the IT industry Uptime Institute, “A technology refresh at the start of the 2020s brought a marked increase in power for the new generation of highly performing and efficient servers that are the foundation of many IT infrastructures. Looking ahead, the rise in server power and cooling needs throws any past assumptions on future power densities and cooling technologies into the air.”yet consumes no water.

Learn More About ThermalWorks

Supporting 200 kW per rack
Our data center cooling systems support up to 70 kW per rack with air cooling and ultra-high densities up to 200 kW with plug and play liquid cooling integration.

Industry Average
(Uptime Institute)
Edged
(air cooling)
Edged
(liquid cooling)
2 Uptime Institute, “A technology refresh at the start of the 2020s brought a marked increase in power for the new generation of highly performing and efficient servers that are the foundation of many IT infrastructures. Looking ahead, the rise in server power and cooling needs throws any past assumptions on future power densities and cooling technologies into the air.”

Carbon neutral

Our facilities will be operationally carbon neutral. We accomplish this with a combination of utility green energy programs, solar and wind PPAs and certified carbon credits. Our mission is to transform data centers into a catalyst for sustainable development.

Learn More

Resources

By clicking “Accept All Cookies”, you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts. View our Privacy Policy for more information.